Hospital compressed air MedBAC

Home > ScienceHospital compressed air MedBAC

MedBAC ™ Medical Breathing Air Control

The MedBac measuring system ensures compliance with the standard and the correct function of the system according to the risk analysis. From a technical point of view, it is possible to detect the filter change intervals and possible oil / water breakthroughs. Monitoring of the residual oil quantity in the compressed air stream is necessary for technical and medical reasons. Once the compressed air line is contaminated with compressor oil, the machine oil is in the line and is continuously distributed in the compressed air network until it finally arrives at the user. This can not be detected without the MedBac measuring technology!

Compressed air, which is used as breathing air according to its intended purpose as a drug, is subject to the requirements of the EUROPEAN MEDICINAL PRODUCT in the area of ​​responsibility of the pharmacist. Elaborate compressed air treatment is to ensure the compressed air quality and, above all, the safety of the patient. This requires PERMANENT MONITORING of compressed air quality in order to ensure permanent compliance with the legal requirements for adherence to the valid limit values ​​of Pharmacopoeia Europea, which became legally binding on 1 August 2001.

To protect the HEALTH OF PATIENTS, to protect medical equipment and compressed air supply systems from costly damage, any malfunction of the compressed air cleaning process must be immediately detected and remedied.

With MedBAC 24-hour online monitoring for medical breathing air, according to the European Pharmacopoeia

The MedBAC ™ helps the pharmacist to perform his duties safely. With MedBAC ™, the production process is permanently monitored and documented in accordance with the medical hygiene requirements and the requirements of GMP.

The compressed air cleaning process is designed to ensure the air quality, availability and safety of patients. With MedBAC ™, the permanent monitoring of compressed air quality becomes real. This measuring procedure also ensures the legal requirements for compliance with the valid limit values of the European Pharmacopoeia.

Continuous monitoring of the production of respiratory air takes place in batches and is permanently recorded.

The modular MedBAC ™ has been specifically designed to monitor the purity of on-site produced breathing air in hospitals. The MedBAC enables immediate detection of malfunctions in the compressed air cleaning processes. The health of patients is effectively protected, medical equipment and compressed air supply systems are protected against costly damage. MedBAC ™ guarantees the all-round safe production of "Aer medicalis" at all times.

TPS performs job measurements and checks of compressed air outlets using the Med-AQM (AirQualityMonitor).

The result can be seen within minutes on site. The technicians and the pharmacists are immediately informed about whether a newly installed compressed air line or terminal can be put into operation. At the same time the qualification of the delivery point takes place.

Any change in the existing compressed air supply must be qualified and assessed for conformity before it can be released!

The operator of his own compressed air generation for ventilation must constantly provide proof of the generated compressed air quality according to the Ph. Eu. provide and document permanently. (ZLG specification since 2007)


TPS helps the operator to ensure a smooth and safe operation for years.